A 10kW carrier is simultaneously modulated by two modulating signals corresponding to a modulation index of 40% and 30%, respectively. The total radiated power will be:
34) A 10kW carrier is simultaneously modulated by two modulating signals corresponding to a modulation index of 40% and 30%, respectively. The total radiated power will be:
Soution
Effective modulation index = sqrt(0.4^2 + 0.3^2) = 0.5
now , Pt = Pc(1+(Effective modulation index)^2/2)
or, Pt = 10kW * 1.125 = 11.25 KW