For a lossless passive two-port network, |S11| and |S21| intersect at –3 dB. For a lossy passive ...
Q. For a lossless passive two-port network, |S11| and |S21| intersect at –3 dB. For a lossy passive two-port network, |S11| and |S21| intersect at – 4 dB.. The percentage of power dissipated in the lossy network at the intersection frequency is __. (rounded off to two decimal places)
Given:
|S11| = |S21| = -4 dB
Step 1: Convert dB into Power Ratio
|S11|2 = |S21|2 = 10-4/10
= 0.398107
Step 2: Calculate Percentage of Power Dissipated
For a passive two-port network:
Pdissipated = (1 - |S11|2 - |S21|2) × 100
Substituting the values:
= (1 - 0.398107 - 0.398107) × 100
= 20.3786%
FINAL ANSWER
20.38%
Percentage of power dissipated in the lossy network